Electric Grease Pump W/ RemoteLinc Technology - P203 Series

Unavailable
SKU: 94423-AC
Regular price $2,158.57
Est. Ship Date: Thursday, August 6th
Reliability Over 50 years in the industry, demonstrating reliability.
Serving customers Serving customers across all 50 states.
Heavy-duty Products designed for heavy-duty use.
Return Policy 30 Days Return Policy*
Trusted By

Product Overview

Lincoln Electric Grease Pump W/ RemoteLinc Technology - P203 Series These pumps are electrically operated and are used in progressive-type automated lubrication systems. The proven and reliable P203 pump has been designed to develop high operating pressures allowing it to supply NLGI #2 grease in most ambient temperatures. Easily interfaces with OEM and aftermarket telematics systems.

Key source specifications include Outlet Connection: 1/8" NPT (f); Reservoir Capacity: 2-, 4-, 8- or 15-liter; Model 94423-AC; Interval Between Lube Cycles: Min. 4 Minutes/Max. 15 hours.

Key Features

  • Outlet Connection: 1/8" NPT (f)
  • Reservoir Capacity: 2-, 4-, 8- or 15-liter
  • Interval Between Lube Cycles: Min. 4 Minutes/Max. 15 hours
  • Pump Output: 0.171 cu. in./min./2.8 cc/min
  • Maximum Recommended Operating Pressure: 5000 psi/350 bar
  • Lubricant: Greases NLGI grade 2 (depending on operating temperature and type of lubricant)

Ideal For

Choose this product if you need:

  • Lubrication systems using Greases NLGI grade 2 (depending on operating temperature and type of lubricant)
  • Systems operating within the listed pressure specifications

Not Ideal For

Not ideal for pressures above the listed 5000 psi/350 bar maximum, lubricants outside the listed Greases NLGI grade 2 (depending on operating temperature and type of lubricant) compatibility, or temperatures outside the listed -13°F to +158°F range.

Product Details

Review the product details below to confirm the outlet connection, reservoir capacity, model / mpn, interval between lube cycles, pump output match your equipment or lubrication system.

Shared Product Details

Brand Lincoln Industrial
Model / MPN 94423-AC
Input 12 VDC @ 3.5 amps, 24 VDC @ 2 amps 94-265 VAC (50 to 60 Hz)
Enclosure Rating IP6KPK
Interval Between Lube Cycles Min. 4 Minutes/Max. 15 hours
Pump Output 0.171 cu. in./min./2.8 cc/min.
Outlet Connection 1/8" NPT (f)
Reservoir Capacity 2-, 4-, 8- or 15-liter
Maximum Recommended Operating Pressure 5000 psi/350 bar
Lubricant Greases NLGI grade 2 (depending on operating temperature and type of lubricant)
Temperature Range -13°F to +158°F
Pressure Relief Valve 4000 psi, ±250 psi/276 bar, ±17 bar

Additional Product Information

Allows users to: Remotely monitor and detect low lubricant levels and system faults. Reduce cost by receiving immediate, real-time alerts when lubricant is low or the system is in fault.

  • Lubricant Outlet: 1/8" NPT (F)
  • Electrical Requirements: 94-265VAC

Frequently Asked Questions

What model number should I verify?

Confirm model or manufacturer part number 94423-AC.

What pressure is listed?

The supplied specifications list 5000 psi/350 bar.

How many outlets are listed?

The supplied specifications list 1/8" NPT (f).

Return Policy

You can return unused or defective products up to 30 days from the date of order.  Some product returns may be subject to restocking fees.  Proof of Purchase will be required if we cannot verify your order information.  Unless the product is defective or damaged in transit, the customer is responsible for return shipment costs.

Defective or Damaged Products

All shipments received must be immediately inspected for damage.  If your order shipped on a freight carrier, any damage needs to be noted on the Freight Receipt before signing for the delivery.  An exchange or refund will be provided at no additional cost.  If damage is due to misuse or regular wear of the product, the return will be denied.

Order Cancellation

If you need to cancel your order for any reason, please contact us immediately.  If the order is canceled prior to shipping, you will be refunded in full.  Certain products that are manufactured to order cannot be canceled after the manufacturing process has started.